2-port CAN interface PC/104-Plus modules with 2 kV isolation
Features and Benefits
- Supports CAN 2.0A and CAN 2.0B
 - Two independent CAN communication ports
 - CAN transfer rate up to 1 Mbps
 - 2 kV electrical isolation
 - LED for transmit/receive status on each port
 - Optional 120-ohm terminal resistor for CAN bus network
 - DLL library and examples included
 -  Windows drivers provided
Introduction
Moxa’s CB-602I CAN (Controller Area Network) interface boards support the PC/104-Plus interface. Optional DB9 and DB25 connection cables are available for connecting to CAN interface devices. The CB-602I CAN interface boards use the NXP SJA1000 and PCA82C251 transceiver, which provide bus arbitration and error detection. The -40 to 85°C wide operating temperature (CB-602I-T only) and 2 kV isolation make the boards suitable for use in harsh industrial environments.
Isolation
2 kV
Max. No. of Boards per PC
8
Baudrate
10/20/50/125/250/500/800/1000 kbps, user-defined
Connector
20-pin box header
No. of Ports
2
Operating Temperature
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
EMC
EN 55032/24
EMI
CISPR 32, FCC Part 15B Class B
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Green Product
RoHS, CRoHS, WEEE
Time
248,563 hrs
Standards
Telcordia (Bellcore), GB
Warranty Period
5 years
Details
 
CB-602I Series
- Brand: MOXA
 - Product Code: CB-602I Series
 - Availability: Please email - info@cayee.com.hk
 